    SM3000RM2UNTAA - Overview

    Tripp Lite SM3000RM2UNTAA SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions.

    Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 98% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and pre-installed SNMPWEBCARD network interface. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions.

    Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.

    • Features:

      • Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
      • Tripp Lite SM3000RM2UNTAA line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity (1600W maximum load with external battery packs)
      • Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V
      • NEMA L5-30P input plug; 8 NEMA 5-15/20R and 1 L5-30R output receptacles, Two independently switchable output load banks
      • Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
      • High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
      • Internal batteries offer 10 minutes at 50% load (1125W) and 3.5 minutes at 100% load (2250W)
      • External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
      • Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
      • Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
      • LCD interface also supports a number of advanced user setup and operating preferences
      • Built-in USB, RS-232 and pre-installed SNMPWEBCARD accessory
      • HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
       
    • Specifications:

      • Output
      • Output Volt Amp Capacity (VA): 3000
      • Output kVA Capacity (kVA): 3
      • Output Watt Capacity (Watts): 2250
      • Output kW Capacity (kW): 2.25
      • Nominal Output Voltage(s) Supported: 110V; 115V; 120V
      • Nominal Voltage Details: 120v nominal output in battery mode
      • Frequency Compatibility: 60 Hz
      • Output Voltage Regulation (Line Mode): -14%, +6%
      • Output Voltage Regulation (Battery Mode): +/- 5%
      • Output Receptacles: (8) 5-15/20R; (1) L5-30R
      • Load Management Receptacles: Two switchable single-outlet load banks
      • Output Circuit Breakers: Two 20A output breakers protect 4 5-15/20R outlets each
      • Output AC Waveform (AC Mode): Pure Sine wave
      • Output AC Waveform (Battery Mode): Pure Sine wave
      • Individually Controllable Load Banks: Yes

        Input
      • Rated input current (Maximum Load): 24A
      • Nominal Input Voltage(s) Supported: 120V AC
      • UPS Input Connection Type: L5-30P
      • UPS Input Cord Length (ft.): 10
      • Recommended Electrical Service: 30A 120V
      • Input Phase: Single-Phase

        Battery
      • Full Load Runtime (min.): 3.5 min. (2250w)
      • Half Load Runtime (min.): 10 min. (1125w)
      • Expandable Battery Runtime: Output with external battery pack configurations is limited to 1600 watts maximum
      • External Battery Pack Compatibility: BP48V24-2U (limit 1); BP48V242UTAA (limit 1); BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible); BP48V60RT3UTAA (multi-pack compatible)
      • DC System Voltage (VDC): 48
      • Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90%
      • Internal UPS Replacement Battery Cartridge: RBC94-2U
      • Battery Access: Front panel battery access door
      • Battery Replacement Description: Hot-swappable, user replaceable batteries

        Voltage Regulation
      • Overvoltage Correction: Input voltages between 127 and 145 are reduced by 12%
      • Undervoltage Correction: Input voltages between 108 and 96 are boosted by 12%
      • Severe Undervoltage Correction: Input voltages between 83 and 95 are boosted by 24%

        Physical
      • Primary Form Factor: Rackmount
      • UPS Power Module Dimensions (hwd, in.): 3.46 x 17.32 x 19.46
      • Rack Height (U Spaces): 2
      • Minimum Required Rack Depth without External Battery Pack (in.): 24.96
      • Minimum Required Rack Depth with External Battery Pack (in.): 26.46
      • UPS Power Module Weight (lbs.): 62.8
      • Shipping Dimensions (hwd / in.): 8.80 x 23.90 x 22.20
      • Shipping Weight (lbs.): 76.40
      • Cooling Method: Fan
      • UPS Housing Material: Steel
      • Operating Temperature Range: +32 to +104 degrees Fahrenheit
      • Storage Temperature Range: +5 to +122 degrees Fahrenheit
      • Relative Humidity: 0 to 95%, non-condensing
      • AC Mode BTU / Hr. (Full Load): 189
      • Battery Mode BTU / Hr. (Full Load): 1356
      • AC Mode Efficiency Rating (100% Load): 98%
      • Operating Elevation (ft.): 0-3000m / 0-10,000 ft.
      • Operating Elevation (m): 0 - 3000 m
       
    • Item Includes:

      • SM3000RM2UNTAA UPS System with Pre-Installed WEBCARDLX Network Interface
      • USB, Serial & EPO cabling
      • 4-post rackmount installation kit
      • Instruction manual
       
    • Warranty:

      • 2 Year
       
    • GTIN:

      0037332184214
       