Tripp Lite SMART5000TEL3U 5000VA 3750W UPS Smart Rackmount AVR 208V 5kVA USB DB9 3URM

ITEM #: TRL-SMT5000TEL3U MFG #: SMART5000TEL3U

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5
Free Shipping with $49 Minimum Order

List Price:

$5,494.32

Our Price:

$3,527.00

Availability: Typically Ships in 3-10 Business Days
iAvailability Description Popup
  • Shipped truck freight.


SMART5000TEL3U - Overview

Tripp Lite's SMART5000TEL3U intelligent, line interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and surges in a compact rackmount housing. Completely self-contained UPS system occupies only 3 rack spaces (3U) in a standard 19 inch rack, making this model one of the smallest 5kVA UPS systems available. Included accessories support mounting 4 post rack enclosures. Large capacity 5000 VA/3750 watt UPS system accepts raw AC input, adjusting output to regulated 208V levels. One pair of 120V outlets support up to 600VA monitors and other low voltage accessories. Includes slot for internal SNMP/web card, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data. Five outlets (two L6-20R, one L6-30R and two 5-15R) allow the connection of high current 20 and 30 amp 208V connectors and up to two 120V devices (max 600VA at 120V).

  • Features:

    • Large 5000VA/3750-watt output capacity accommodates solitary large loads or multiple low-power loads
    • High power density 5kVA power module occupies only 3 rack spaces(3U)
    • 16 minutes half-load runtime(with a continuous load 2500VA; much longer runtime available at smaller loads)
    • Line-interactive voltage regulation corrects severe brownouts and overvoltages without using battery power
     
  • Specifications:

    • Output Volt Amp Capacity (VA) 5000
    • Output kVA Capacity (kVA) 5
    • Output Watt Capacity (Watts) 3750
    • Output kW Capacity (kW) 3.75
    • Power Factor 0.75
    • Nominal Output Voltage(s) Supported 120V; 208V
    • Frequency Compatibility 60 Hz
    • Output Voltage Regulation (Line Mode) 208 & 120V (+/- 10%)
    • Output Voltage Regulation (Battery Mode) +/- 5%
    • Output Receptacles (8) 5-15/20R; (2) L6-20R; (1) L6-30R
    • Load Management Receptacles Eight switchable single-outlet 5-15/20R load banks
    • Output Circuit Breakers 20A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered
    • Output AC Waveform (AC Mode) Sine wave
    • Output AC Waveform (Battery Mode) Pure Sine wave
    • Rated input current (Maximum Load) 24A
    • Nominal Input Voltage(s) Supported 208V AC
    • UPS Input Connection Type L6-30P
    • UPS Input Cord Length (ft.) 10
    • UPS Input Cord Length (m) 3
    • Recommended Electrical Service 30A 208V
    • Input Phase Single-Phase
    • Full Load Runtime (min.) 8.5 min. (3750w)
    • Half Load Runtime (min.) 20 min. (1875w)
    • Expandable Battery Runtime Extended runtime supported via optional external battery packs
    • External Battery Pack Compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
    • DC System Voltage (VDC) 48
    • Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
    • Internal UPS Replacement Battery Cartridge RBC94-3U (quantity 3)
    • Battery Access Front panel battery access door
    • Battery Replacement Description Hot-swappable, user replaceable batteries
    • Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260
    • Overvoltage Correction Input voltages between 228 and 260 are reduced by 12%
    • Undervoltage Correction Input voltages between 167 and 194 are boosted by 12%
    • Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
    • Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
    • Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
    • LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
    • UPS AC Suppression Joule Rating 1020
    • UPS AC Suppression Response Time Instantaneous
    • EMI / RFI AC Noise Suppression Yes
    • Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
    • Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
    • Primary Form Factor Rackmount
    • UPS Power Module Dimensions (hwd, in.) 5.2 x 17.5 x 25
    • UPS Power Module Dimensions (hwd, cm) 13.3 x 44.4 x 63.5
    • Installed Whole System Maximum Rack Depth (in.) 25
    • Installed Whole System Maximum Rack Depth (cm) 63.5
    • Rack Height (U Spaces) 3
    • UPS Power Module Weight (lbs.) 143.3
    • UPS Power Module Weight (kg) 65.1
    • UPS Shipping Dimensions (hwd / in.) 11.2 x 23 x 31.5
    • UPS Shipping Dimensions (hwd / cm) 28.6 x 58.4 x 80
    • Shipping Weight (lbs.) 181.9
    • Shipping Weight (kg) 82.6
    • Cooling Method Fan
    • UPS Housing Material Steel
    • Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    • Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    • Relative Humidity 0 to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load) 671.1
    • AC Mode Efficiency Rating (100% Load) 0.97
    • Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
    • Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
    • PowerAlert Software Included
    • Communications Cable USB and DB9 cabling included
    • WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
    • Transfer Time 7 ms (AC to Battery); 1 ms (Battery to AC) typical
    • Low Voltage Transfer to Battery Po
     
  • GTIN:

    0037332116116
     