SU6000RT4UHVG - Overview

Tripp Lite SU6000RT4UHVG 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable whole UPS replacement with no interruption to connected equipment. Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire input and 4 C19 outlets. Support for optional North American and International cordsets.


What does Uninterruptible Power Supply (UPS) mean?
An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
-Save your work, and
-Shut down your computer.
Please Note: A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to save and do an orderly shutdown.

  • Specifications:

    • Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
    • Output Volt Amp Capacity (VA) 6000
    • Output kVA Capacity (kVA) 6
    • Output Watt Capacity (Watts) 5400
    • Output kW Capacity (kW) 5.4
    • Power Factor 0.9
    • Crest Factor 0.125694444444444
    • Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
    • Nominal Voltage Details Voltage selection via front panel LCD interface
    • Frequency Compatibility 50 / 60 Hz
    • Battery Access Front panel battery access door
    • Battery Replacement Description Hot-swappable, user replaceable internal batteries
    • Voltage Regulation Description Online, double-conversion power conditioning
    • Overvoltage Correction Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
    • Undervoltage Correction Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
    • Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
    • Switches Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
    • Alarm Cancel Operation Alarm cancel switch
    • Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
    • LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
    • UPS AC Suppression Response Time Instantaneous
    • EMI / RFI AC Noise Suppression Yes
    • AC Suppression Response Time NULL
    • Included Mounting Accessory Description 4 post rackmount installation accessories included
    • Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
    • Primary Form Factor Rackmount
    • UPS Power Module Dimensions (hwd, in.) 6.85 x 17.5 x 20.7
    • UPS Power Module Dimensions (hwd, cm) 17.4 x 44.5 x 52.6
    • Installed Whole System Maximum Rack Depth (in.) 20.7
    • Installed Whole System Maximum Rack Depth (cm) 52.6
    • Rack Height (U Spaces) 4
    • UPS Power Module Weight (lbs.) 116.2
    • UPS Power Module Weight (kg) 52.8
    • UPS Shipping Dimensions (hwd / in.) 12.7 x 23.6 x 29.1
    • UPS Shipping Dimensions (hwd / cm) 32.3 x 59.9 x 73.9
    • Shipping Weight (lbs.) 157
    • Shipping Weight (kg) 71.1
     
  • GTIN:

    0037332157232
     

SU6000RT4UHVG - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov